1. Y. Yeh, F.H. de Moura, K. Van Den Broek, and A.S. de Mello, "Effect of ultraviolet light, organic acids, and bacteriophage on Salmonella populations in ground beef," Meat Sci. Vol. 139, pp. 44-48, 2018. [
DOI:10.1016/j.meatsci.2018.01.007] [
PMID]
2. J.D. Fuentes, T.H. Roulston, and J. Zenker, "Ozone impedes the ability of a herbivore to find its host," Environ. Res. Lett. Vol. 8, pp. 014048 (1-5), 2013. [
DOI:10.1088/1748-9326/8/1/014048]
3. J. (Jim) Zhang, Y. Wei, and Z. Fang, "Ozone Pollution: A Major Health Hazard Worldwide," Front. Immunol. Vol. 10, pp. 2518 (1-10), 2019. [
DOI:10.3389/fimmu.2019.02518] [
PMID] [
PMCID]
4. M.T. Ching En, I.M. Haniff, and N.N. Hafizah, "Measurements of ozone absorption cross section with ratiometric and non-ratiometric methods," Ukr. J. Phys. Opt. Vol. 16, no. 1, pp. 61-67, 2015. [
DOI:10.3116/16091833/16/1/61/2015]
5. A.L. Gomez and E.P. Rosen, "Fast response cavity enhanced ozone monitor," Atmos. Meas. Tech. Vol. 6, no. 2, pp. 487-494, 2013. [
DOI:10.5194/amt-6-487-2013]
6. R. Washenfelder, N. Wagner, W. Dubé, and S. Brown, "Measurement of Atmospheric Ozone by Cavity Ring-down Spectroscopy," Environ. Sci. Technol. Vol. 45, pp. 2938-2944, 2011. [
DOI:10.1021/es103340u] [
PMID]
7. S. Böttger, M. Köhring, U. Willer, and W. Schade, "Off-beam quartz-enhanced photoacoustic spectroscopy with LEDs," Appl. Phys. B, Vol. 113, pp. 1-6, 2013. [
DOI:10.1007/s00340-013-5462-x]
8. J. Buffle, "Chapter 3: Gas Laws and the Kinetic Theory," The Pressure of a Gas, 2016.
9. M. David, M.H. Ibrahim, S.M. Idrus, N.H. Ngajikin, A.I. Azmi, and T.C.E. Marcus, "Optical path-length, temperature, and wavelength effects simulation on ozone gas absorption cross sections towards green communications," J. Electron. Sci. Technol. Vol. 14, no. 3, pp. 199-204, 2016.
10. J.P. Burrows, M. Buchwitz, V. Rozanov, M. Weber, A. Richter, and A. Ladstätter-Weißenmayer, "The Global Ozone Monitoring Experiment (GOME): Mission, instrument concept, and first scientific results," Eur. Sp. Agency, (Special Publ. ESA SP, no. 414 PART 2, pp. 585-590, 1997.
11. J. Viallon, S. Lee, P. Moussay, K. Tworek, M. Petersen, and R.I. Wielgosz, "Accurate measurements of ozone absorption cross sections in the Hartley band," Atmos. Meas. Tech., Vol. 8, no. 3, pp. 1245-1257, 2015. [
DOI:10.5194/amt-8-1245-2015]
12. T.C.E. Marcus, M.H. Ibrahim, N.H. Ngajikin, and A.I. Azmi, "Optical path-length and absorption cross section optimization for high sensitivity ozone concentration measurement," Sensors Actuators, B Chem. Vol. 221, pp. 570-575, 2015. [
DOI:10.1016/j.snb.2015.07.005]
13. L. De Maria and D. Bartalesi, "A Fiber-Optic Multisensor System for Predischarges Detection on Electrical Equipment," IEEE Sens. J. Vol. 12, no. 1, pp. 207-212, 2012. [
DOI:10.1109/JSEN.2011.2147303]
14. E. Patrick, M. David, C.O. Alenoghena, S.A. Bala, and A. Joshua, "Comparative Study of the Effect of Sensing Parameters on Ozone Gas Comparative Study of the Effect of Sensing Parameters on Ozone Gas Absorption-Cross section," in 2nd International Engineering Conference IEC, Vol. 1, pp. 284-290, 2017.
15. Y. Aoyagi , M. Takeuchi , K. Yoshida , M. Kurouchi , T. Araki , Y. Nanishi , H. Sugano , Y. Ahiko, and H. Nakamura., "High-Sensitivity Ozone Sensing Using 280 nm Deep Ultraviolet Light-Emitting Diode for Detection of Natural Hazard Ozone," J. Environ. Prot. (Irvine,. Calif)., Vol. 03, no. 08, pp. 695-699, 2012. [
DOI:10.4236/jep.2012.38082]
16. F. Berger, B. Ghaddab, J.B. Sanchez, and C. Mavon, "Development of an ozone high sensitive sensor working at ambient temperature," J. Phys. Conf. Ser. Vol. 307, no. 1, pp. 012054 (1-3), 2011. [
DOI:10.1088/1742-6596/307/1/012054]
17. A.D McNaught, A. Wilkinson, and A.D. Jenkins, Compendium of Chemical Terminology-The "Gold Book," 2nd ed. Blackwell Scientific Publications, Oxford, 2006.